Profile lets you retrieve all the prove data from the Omni to store and stores it in the Profile database. The Omni 6000 only allows the most recent prove to be downloaded so the archive registers must be setup to allow Profile to download all the prove data.
Requirements:
Profile v3.2.0
To setup the archive registers:
Open OmniCom
Select 'Online' from the 'Actions' menu.

Press the 'Connect' button.
Select 'Operate' from the 'Actions' menu.
Choose 'Archive Maintenance' from the 'Operate' sidebar.

Click the 'Stop' button in the 'Archiving Status' to stop the archive from running.
Then click the 'Enable' button in the 'Archive Configuration Status' section to allow the archives to be edited.
Select 'Configure' from the 'Actions' menu.

Expand 'Archives' from the sidebar.
Select one of the Archives.
Set the Boolean Trigger to be 1928 and enter the max records that you want to store eg 50.
Add the following packets to the archive. The Prover Prove Report Number field must be in the first packet.
| Packet | Point No |
Description | Point Count |
Data Type |
| 1 | 5931 | Prover Prove Report Number | 1 | 32 Bit Integer |
| 2 | 4921 | Prover Prove Date | 2 | 8 Byte ASCII |
| 3 | 4905 | Prover Prove Meter - Serial Number | 1 | 8 Byte ASCII |
| 4 | 3902 | Prover Proving Meter Number | 1 | 16 Bit Integer |
| 5 | 4901 | Prover Prove Meter - Product Name | 1 | 8 Byte ASCII |
| 6 | 5963 | Prover Actual Meter Factor - Current Prove | 1 | 32 Bit Integer |
| 7 | 8058 | Prover Counts/Meter Factor % Deviation Between Runs | 1 | Float |
| 8 | 8071 | Prover MF Deviation % From Previous MF | 1 | Float |
| 9 | 7964 | Prover K Factor (Average Runs) | 1 | Float |
| 10 | 8072 | Prover Actual K Factor | 1 | Float |
| 11 | 8059 |
Prover Ctsp |
5 | Float |
| 12 | 8066 |
Prover Ctlm |
3 | Float |
| 13 | 8069 | Prover Corrected Meter Volume | 1 | Float |
These fields must correlate with how Profile has been configured.
Click the 'Apply' button.
Go back to the operate screen and select 'Archive Maintenance'.
Disable the Archive Configuration.
Enable the Archiving.
On the Profile server:
Select 'Configurations' from the 'Config' menu.

Double click on the configuration that you want to edit.

Click on the 'Proves' button.

Add the fields to the Proves screen so that they correspond with the fields set up in the archive.
When a prove completes the data will be collected from the archive registered and presented for the flow computer.