Forums/Tips & Tricks

Profile: Setting up Omni 6000 Archive Registers to store prove data

Andrew Webb
posted this on April 04, 2011 15:36

 

Profile lets you retrieve all the prove data from the Omni to store and stores it in the Profile database. The Omni 6000 only allows the most recent prove to be downloaded so the archive registers must be setup to allow Profile to download all the prove data.

 

Requirements:

Profile v3.2.0

 

To setup the archive registers:

Open OmniCom

Select 'Online' from the 'Actions' menu.

Screen_shot_2011-04-04_at_13.34.47.png

Press the 'Connect' button.

Select 'Operate' from the 'Actions' menu.

Choose 'Archive Maintenance' from the 'Operate' sidebar.

Screen_shot_2011-04-04_at_13.26.58.png

Click the 'Stop' button in the 'Archiving Status' to stop the archive from running.

Then click the 'Enable' button in the 'Archive Configuration Status' section to allow the archives to be edited.

Select 'Configure' from the 'Actions' menu.

Screen_shot_2011-04-04_at_13.44.22.png

 

Expand 'Archives' from the sidebar.

Select one of the Archives.

Set the Boolean Trigger to be 1928 and enter the max records that you want to store eg 50.

Add the following packets to the archive. The Prover Prove Report Number field must be in the first packet.

Packet Point
No
Description Point
Count
Data Type
1 5931 Prover Prove Report Number 1 32 Bit Integer
2 4921 Prover Prove Date 2 8 Byte ASCII
3 4905 Prover Prove Meter - Serial Number 1 8 Byte ASCII
4 3902 Prover Proving Meter Number 1 16 Bit Integer
5 4901 Prover Prove Meter - Product Name 1 8 Byte ASCII
6 5963 Prover Actual Meter Factor - Current Prove 1 32 Bit Integer
7 8058 Prover Counts/Meter Factor % Deviation Between Runs 1 Float
8 8071 Prover MF Deviation % From Previous MF 1 Float
9 7964 Prover K Factor (Average Runs) 1 Float
10 8072 Prover Actual K Factor 1 Float
11 8059

Prover Ctsp
Prover Cpsp
Prover Ctlp
Prover CCFp
Prover Corrected Prover Volume

5 Float
12 8066

Prover Ctlm
Prover Cplm
Prover CCFm

3 Float
13 8069 Prover Corrected Meter Volume 1 Float

 

These fields must correlate with how Profile has been configured.

Click the 'Apply' button.

Go back to the operate screen and select 'Archive Maintenance'.

Disable the Archive Configuration.

Enable the Archiving.

 

On the Profile server:

Select 'Configurations' from the 'Config' menu.

Screen_shot_2011-04-04_at_14.34.28.png

 

Double click on the configuration that you want to edit.

 

Screen_shot_2011-04-04_at_14.34.35.png

 

Click on the 'Proves' button.

 

Screen_shot_2011-04-04_at_14.38.51.png

 

Add the fields to the Proves screen so that they correspond with the fields set up in the archive.

When a prove completes the data will be collected from the archive registered and presented for the flow computer.

 
Topic is closed for comments